Difference between revisions of "How to Turn STIX On (PDOR)"
Daniel.ryan (talk | contribs) (Created page with "If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. ==Generating a PDOR== * Open STIX-Starlet * In top toolb...") |
Daniel.ryan (talk | contribs) |
||
Line 7: | Line 7: | ||
* Set start and end time | * Set start and end time | ||
* Enter telecommand sequences (recommended) by clicking the Add Sequence button | * Enter telecommand sequences (recommended) by clicking the Add Sequence button | ||
− | + | ** Alternatively enter individual telecommands by clicking the Add Telecommand button | |
+ | |||
+ | ==Telecommands for Turning STIX On== | ||
+ | Below are the telecommand sequences for turning STIX back on. Extra things can be done as part of the PDOR, e.g. changing onboard parameters. But this is the minimal list. | ||
+ | * AIXF011A (Turns STIX on and puts it into Safe mode) | ||
+ | * AIXF032A (Switches from safe to nominal mode) | ||
+ | * AIXF400A (Enables calibration accumulation) |
Revision as of 14:45, 4 November 2022
If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on.
1 Generating a PDOR
- Open STIX-Starlet
- In top toolbar, click Request -> New Request
- Click Request -> PDOR (under Mode)
- Set start and end time
- Enter telecommand sequences (recommended) by clicking the Add Sequence button
- Alternatively enter individual telecommands by clicking the Add Telecommand button
2 Telecommands for Turning STIX On
Below are the telecommand sequences for turning STIX back on. Extra things can be done as part of the PDOR, e.g. changing onboard parameters. But this is the minimal list.
- AIXF011A (Turns STIX on and puts it into Safe mode)
- AIXF032A (Switches from safe to nominal mode)
- AIXF400A (Enables calibration accumulation)