If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on.
+
If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. Previously used PDORs are available in the [https://datacenter.stix.i4ds.net/view/ior/list IOR Manager] on the STIX website.  To create one from scratch, see [[How to Write a PDOR]].
 
 
==Generating a PDOR==
 
* Open [[STIX-Starlet]]
 
* In top toolbar, click Request -> New Request
 
* Click Request -> PDOR (under Mode)
 
* Set start and end time
 
* Enter telecommand sequences (recommended) by clicking the Add Sequence button
 
** Alternatively enter individual telecommands by clicking the Add Telecommand button
 
  
 
==Telecommands for Turning STIX On==
 
==Telecommands for Turning STIX On==
Below are the telecommand sequences for turning STIX back on.  Extra things can be done as part of the PDOR, e.g. changing onboard parameters.  But this is the minimal list.
+
Below are the telecommand sequences that must be included in the PDOR to turn STIX on.  Extra things can be done as part of the PDOR, e.g. changing onboard parameters.  But this is the minimal list.
 
* AIXF011A (Turns STIX on and puts it into Safe mode)
 
* AIXF011A (Turns STIX on and puts it into Safe mode)
 
* AIXF032A (Switches from safe to nominal mode)
 
* AIXF032A (Switches from safe to nominal mode)
 
* AIXF400A (Enables calibration accumulation)
 
* AIXF400A (Enables calibration accumulation)

Revision as of 14:53, 4 November 2022

If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. Previously used PDORs are available in the IOR Manager on the STIX website. To create one from scratch, see How to Write a PDOR.

Telecommands for Turning STIX On

Below are the telecommand sequences that must be included in the PDOR to turn STIX on. Extra things can be done as part of the PDOR, e.g. changing onboard parameters. But this is the minimal list.

  • AIXF011A (Turns STIX on and puts it into Safe mode)
  • AIXF032A (Switches from safe to nominal mode)
  • AIXF400A (Enables calibration accumulation)