Difference between revisions of "How to Turn STIX On (PDOR)"
Daniel.ryan (talk | contribs) |
Daniel.ryan (talk | contribs) |
||
Line 1: | Line 1: | ||
− | If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. | + | If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. Previously used PDORs are available in the [https://datacenter.stix.i4ds.net/view/ior/list IOR Manager] on the STIX website. To create one from scratch, see [[How to Write a PDOR]]. |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Telecommands for Turning STIX On== | ==Telecommands for Turning STIX On== | ||
− | Below are the telecommand sequences | + | Below are the telecommand sequences that must be included in the PDOR to turn STIX on. Extra things can be done as part of the PDOR, e.g. changing onboard parameters. But this is the minimal list. |
* AIXF011A (Turns STIX on and puts it into Safe mode) | * AIXF011A (Turns STIX on and puts it into Safe mode) | ||
* AIXF032A (Switches from safe to nominal mode) | * AIXF032A (Switches from safe to nominal mode) | ||
* AIXF400A (Enables calibration accumulation) | * AIXF400A (Enables calibration accumulation) |
Revision as of 14:53, 4 November 2022
If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. Previously used PDORs are available in the IOR Manager on the STIX website. To create one from scratch, see How to Write a PDOR.
Telecommands for Turning STIX On
Below are the telecommand sequences that must be included in the PDOR to turn STIX on. Extra things can be done as part of the PDOR, e.g. changing onboard parameters. But this is the minimal list.
- AIXF011A (Turns STIX on and puts it into Safe mode)
- AIXF032A (Switches from safe to nominal mode)
- AIXF400A (Enables calibration accumulation)