− | Below are the telecommand sequences that must be included in the PDOR to turn STIX on. The wait times before the next sequence is also | + | Below are the telecommand sequences that must be included in the PDOR to turn STIX on. The wait times before the next sequence is also given. These wait time must be adhered to or the execution of the sequennces could be interrupted. Extra things can be done as part of the PDOR, e.g. changing onboard parameters, but this is the minimal list. |
* AIXF011. Wait time: 30 mins (Turns STIX on and puts it into Safe mode) | * AIXF011. Wait time: 30 mins (Turns STIX on and puts it into Safe mode) | ||
* AIXF032A. Wait time: 1 minute (Switches from safe to nominal mode) | * AIXF032A. Wait time: 1 minute (Switches from safe to nominal mode) | ||
* AIXF400A. Wait time: a few seconds (Enables calibration accumulation) | * AIXF400A. Wait time: a few seconds (Enables calibration accumulation) |
Latest revision as of 14:58, 4 November 2022
If STIX has been turned off, e.g. because of an issue on the satellite, we need create a PDOR to turn it back on. Previously used PDORs are available in the IOR Manager on the STIX website. To create one from scratch, see How to Write a PDOR.
Telecommands for Turning STIX On
Below are the telecommand sequences that must be included in the PDOR to turn STIX on. The wait times before the next sequence is also given. These wait time must be adhered to or the execution of the sequennces could be interrupted. Extra things can be done as part of the PDOR, e.g. changing onboard parameters, but this is the minimal list.
- AIXF011. Wait time: 30 mins (Turns STIX on and puts it into Safe mode)
- AIXF032A. Wait time: 1 minute (Switches from safe to nominal mode)
- AIXF400A. Wait time: a few seconds (Enables calibration accumulation)